Monday, April 30, 2012

Malignant Pleural Disease: Diagnosis by Using Diffusion-weighted and Dynamic Contrast-enhanced MR Imaging--Initial Experience

http://www.ncbi.nlm.nih.gov/pubmed/22535562


Radiology. 2012 Apr 24. [Epub ahead of print]

Malignant Pleural Disease: Diagnosis by Using Diffusion-weighted and Dynamic Contrast-enhanced MR Imaging--Initial Experience.

Source

Departments of Radiology, Thoracic Surgery, Pneumology, and Pathology, University Hospitals Leuven, Herestraat 49, B-3000 Leuven, Belgium.

Abstract

Purpose:
To investigate the use of diffusion-weighted (DW) imaging for differentiating benign lesions from malignant pleural disease (MPD) and to retrospectively assess dynamic contrast material-enhanced (DCE) magnetic resonance (MR) imaging acquisitions to find out whether combining these measurements with DW imaging could improve the diagnostic value of DW imaging.

Materials and Methods:
This study was approved by the local ethics committee, and all patients provided written informed consent. Thirty-one consecutive patients with pleural abnormalities suspicious for MPD underwent whole-body positron emission tomography (PET)/computed tomography (CT) and thorax MR examinations. Diagnostic thoracoscopy with histopathologic analysis of pleural biopsies served as the reference standard. First-line evaluation of each suspicious lesion was performed by using the apparent diffusion coefficient (ADC) calculated from the DW image, and the optimal cutoff value was found by using receiver operating characteristic curve analysis. Afterward, DCE MR imaging data were used to improve the diagnosis in the range of ADCs where DW imaging results were equivocal.

Results:
Sensitivity, specificity, and accuracy of PET/CT for diagnosis of MPD were 100%, 35.3%, and 64.5%. The optimal ADC threshold to differentiate benign lesions from MPD with DW MR imaging was 1.52 × 10(-3) mm(2)/sec, with sensitivity, specificity, and accuracy of 71.4%, 100%, and 87.1%, respectively. This result could be improved to 92.8%, 94.1%, and 93.5%, respectively, when DCE MR imaging data were included in those cases where ADC was between 1.52 and 2.00 × 10(-3) mm(2)/sec. A total of 20 patients had disease diagnosed correctly, nine had disease diagnosed incorrectly, and two cases were undetermined with PET/CT. DW imaging helped stage disease correctly in 27 patients and incorrectly in four. The undetermined cases at PET/CT were correctly diagnosed at MR imaging.

Conclusion:
DW imaging is a promising tool for differentiating MPD from benign lesions, with high accuracy, and supplementation with DCE MR imaging seems to further improve sensitivity.

No comments:

Post a Comment